MODEL 751
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installationworkandelectricalwiringmustbedonebyaqualied
person(s) in accordance with all applicable codes and standards,
includingre-ratedconstructioncodesandstandards.
4. Sufcientairisneededforpropercombustionandexhaustingof
gasesthroughtheue(chimney)offuelburningequipmenttopre-
vent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electri-
cal wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(GroundFaultCircuitInterrupter)-protectedbranchcircuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. To reduce the risk of electrical shock, do not use this fan with
anysolid-statespeedcontrol.
10. Not for use in kitchens.
11.DonotinstallinaceilinginsulatedtoavaluegreaterthanR-
40.
12. This unit must be grounded.
CAUTION
1. Forgeneralventilatinguseonly.Donotusetoexhausthazard-
ousorexplosivematerialsandvapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Pleasereadspecicationlabelonproductforfurtherinformation
and requirements.
VENTILATION FAN
WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
FOR BEST RESULTS
WheninstallingtheExhaustFan/Lightinanewconstructionsite,
installhousingduringtherough-inconstructionofthebuilding.The
blowerunit,reectorandgrilleshouldbeinstalledafterthenished
ceiling is in place.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4” round duct.
2. Plan duct run from discharge opening of fan to the outside. For
best fan performance, make duct run as short as possible and
use minimum number of elbows.
3. Use optional Broan ducting accessories as needed.
WIRING
Plan to run 120 VAC house wiring (with ground) from power source,
throughwallswitch,tojunctionboxinhousing.Forseparatecontrol
of fan and light use an optional Broan switch.
IMPORTANT: Use wire suitable for 90
o
C.
Wiring
Knockouts
FIGURE 1
Housing
Scroll
Slots
Power/Blower
Unit
Reflector
Assembly
Acorn Nut
Grille/Lens
Assembly
Mounting
Springs (2)
Duct
Collar
Tabs
Hanger Bars