INSTALL FRESH AIR INLETS
1. Add framing to ceiling joists as shown.
2. Set ventilator in place and screw it to framing with screws
provided. Ventilator may also be hung from ceiling joists
or rafters with hanging straps (available separately).
CEILING
JOISTS
2 X 4
FRAMING
CEILING
JOISTS
2 X 4
FRAMING
CONNECT DUCTWORK
6" ROUND
INSULATED
FLEXIBLE
DUCT
FROM
DIFFUSER
1. Run 6" insulated, flexible ductwork from ventilator inlet
to diffuser location(s) and from ventilator outlet to roof or
wall cap. Outlet side is marked with a label.
2. To minimize condensation inside of ductwork in the at-
tic, cover ductwork with additional insulation. Also, avoid
forming condensation traps in the ductwork runs.
3. Seal ductwork to ventilator and roof or wall cap with duct
tape or clamp (available separately)
WIRE THE VENTILATOR
TO ROOF OR
WALL CAP
DUCT
TAPE OR CLAMP
WARNING: DISCONNECT POWER AT SERVICE
ENTRANCE AND LOCK OUT SERVICE PANEL
TO PREVENT POWER FROM BEING SWITCHED
ON ACCIDENTALLY.
Use an ON/OFF switch to control the in-line ventilator.
Accessory timers and humidity controls are also available.
1. Remove the wiring adapter plate.
2. Attach power cable to wiring adapter plate using U.L./
CSA approved connector.
3. Connect black to black, white to white, and green or bare
wire to green ground screw.
4. Replace wiring adapter plate. Make sure tab on housing
slides through slot in plate.
ON/OFF
SWITCH
120 VAC
LINE IN
WIRING ADAPTER
PLATE
BLACK
GROUND
(Green or
Bare Wires)
GROUND
WIRE
WHITE
OR
1. Mount all fresh air inlets in chosen locations during
rough-in construction. Follow directions packed with
inlets.
MOUNT THE VENTILATOR
OUTLET
SIDE
BLACK
BLACK