MODELS 345SOBK • 345SOWW
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, disable the ventilator by cover-
ing the solar panel with cardboard or disconnecting the wires
from the motor terminals (note wire locations when disconnect-
ing).
3. Installation work must be done by a qualified person(s) in ac-
cordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. If removing an existing 120 VAC powered attic ventilator, use
only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guidelines and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations
readily accessible to people or animals.
4. This ventilator operates when the solar panel is exposed to
sun light. To reduce risk of injury while installing, servicing or
cleaning unit, cover the solar panel with cardboard or discon-
nect the wires from the motor terminals (note wire locations
when disconnecting).
5. The recommended open air inlet for this ventilator is 2 square
feet. The best location for these air intake vents are under the
eaves with direct access to the attic. Failure to provide these
intakes could cause natural-draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a
light spray of rain into this attic space. This is a normal condi-
tion with all attic ventilators and will not cause any damage to
the structure. We recommend that you do not store any valu-
able articles directly under the fan opening in the roof.
7. This ventilator is intended for roof installation. Broan Models
353, 345GOBK & 345GOWW Gable Mount Ventilators are
available for side wall applications.
8. The plastic ventilator dome and base may be painted with
high quality paint. Follow the paint manufacturer's recommen-
dations for acrylic and ABS plastic as appropriate. Take care
to avoid getting paint on the solar panel.
9. This ventilator includes a permanently lubricated motor. Do
not oil or disassemble.
10. The installation instructions contained in this document are
only a recommendation and individual professionals may
have their own methods of installation. If your roof has an
existing warranty, installation of this product by anyone other
than those who installed the roof may jeopardize any future
warranty claim. Please check with the original installer of your
roof if this is a concern.
11. When working with asphalt shingles in cold weather (below
40
o
F), take care to avoid damage to the shingle edges and
corners.
12. For installations in climates where cold weather condensation
is not a concern, Broan Model CWT45 thermostat is available.
It disconnects power to the motor when the temperature drops
below 50
o
F. Power is applied to the motor when the tempera-
ture reaches 61
o
F.
ROOF-MOUNT
SOLAR POWERED
ATTIC VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
r
Drill
r
1/4" Drill Bit
r
Sabre Saw or Keyhole Saw
r
Hammer
r
Ruler / Tape Measure
r
Pencil, Marker or Scribe
r
Utility Knife
r
Pry Bar (to remove roofing nails)
r
5/16" Socket and Extension
r
Roofing Cement
r
Galvanized Roofing Nails (1¾" min.)
TOOLS AND MATERIALS REQUIRED
Register your product online at:
www.broan.com/register
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - ATTIC VENTILATOR

MODELS 345SOBK • 345SOWWPage 1WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit

Strany 2 - INSTALLATION

MODÈLES 345SOBK • 345SOWWPage 1013. Assurez-vous que la base du ventilateur est parallèle à la ligne du faîte, soulevez délicatement les bardeaux et

Strany 3 - MODELS 345SOBK • 345SOWW

MODÈLES 345SOBK • 345SOWWPage 11Modèle Modèle Repère 345SOBK 345SOWW Description (noir) (bois intempérisé)1 77001311 77001313 Ensemble de

Strany 4

MODÈLES 345SOBK • 345SOWWPage 1279040170CGARANTIEBROAN-NUTONE LLC – Garantie exclusive limitée – Le contrat de garantie exclusive limitée (la « Gar

Strany 5 - SERVICE PARTS

MODELOS 345SOBK • 345SOWWPágina 13ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, SIGA LAS

Strany 6 - WARRANTY

MODELOS 345SOBK • 345SOWWPágina 144. Desde el interior del ático, encuentre la ubicación deseada para el ventilador y marque un punto a la mitad en

Strany 7 - MONTÉSUR LE TOIT

MODELOS 345SOBK • 345SOWWPágina 157. Recorte las tejas dentro del círculo.8. Usando el mismo clavo y el cordón indicados en el paso 6, marque un c

Strany 8

MODELOS 345SOBK • 345SOWWPágina 1613. Asegúrese de que la base del ventilador esté paralela a la saliente del techo, y con cuidado levante las tejas

Strany 9

MODELOS 345SOBK • 345SOWWPágina 17Modelo Modelo Clave 345SOBK 345SOWW Descripción N.o (Negro) (Madera curtida)1 77001311 77001313 Conjunt

Strany 10 - MODÈLES 345SOBK • 345SOWW

MODELOS 345SOBK • 345SOWWPágina 1879040170CGARANTÍABROAN-NUTONE LLC – Garantía limitada exclusiva –El Convenio de Garantía Limitada Exclusiva (la &

Strany 11 - PIÈCES DE RECHANGE

MODELS 345SOBK • 345SOWWPage 24. Working from the inside of your attic, find the desired ventilator location and mark a spot halfway between rafter

Strany 12 - GARANTIE

MODELS 345SOBK • 345SOWWPage 37. Cut out the shingles inside of the circle.8. Using the same nail and string shown in step 6, scribe a 14” diamete

Strany 13 - ENELTECHO

MODELS 345SOBK • 345SOWWPage 413. Make sure the ventilator base is parallel to the roof ridge, carefully lift shingles and nail or screw base secure

Strany 14 - INSTALACIÓN

MODELS 345SOBK • 345SOWWPage 5Model Model Key 345SOBK 345SOWW Description No. (Black) (Weathered Wood)1 77001311 77001313 Solar Panel Assem

Strany 15 - Página 15

MODELS 345SOBK • 345SOWWPage 6WARRANTYBROAN-NUTONE LLC – Exclusive Limited Warranty –The Exclusive Limited Warranty Agreement (the “Warranty”) is en

Strany 16 - Página 16

MODÈLES 345SOBK • 345SOWWPage 7AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE

Strany 17 - PIEZAS DE SERVICIO

MODÈLES 345SOBK • 345SOWWPage 84. De l'intérieur du grenier, trouvez l'endroit voulu et marquez un point à mi-chemin entre deux chevrons

Strany 18 - GARANTÍA

MODÈLES 345SOBK • 345SOWWPage 97. Coupez les bardeaux à l'intérieur du cercle.8. En utilisant toujours l'avant-trou de l’étape 6 comme p

Komentáře k této Příručce

Žádné komentáře